Skip to main content

Lab Book 2014_05_12 Sample Frame Design and Missing Liquid Nitrogen

Lab Book 2014_05_12     Hamilton Carter

To Do this week in no particular order:
1.       Leak detect the glass and fiberglass Dewars
2.       Check on the availability of the can crusher
3.       Make drawings for sample stage
4.       Check for existing materials that might be used for the sample stage
5.       Find 240 V 3 phase outlet for the magnet power supply
6.       Get the power cord for the magnet supply
7.       Modify lab table
8.       Move magnet
9.       Continue review of the Nikolic paper concentrating on equations 8 - 11
10.   Continue work on the Thomas precession paper
11.   Check on replacement filters for the leak detector
12.   Move and test NaI detector
13.   Characterize source in Dewar with NaI detector
14.   Magnet test YBCO sample
15.   Find a source for x-ray film and developing

Done Today
Reseated the top and bottom seals on the fiberglass Dewar.  Spent some time brainstorming how to mount the sample in the fiberglass Dewar.



Dewar Design Decision:
The Dewar will not be cut or modified to house a larger sample than can be inserted through the neck.  The sample will be situated in the tail of the Dewar.


Brainstorming sketching.  The coil will be oriented with its axis of rotation directed horizontally.  The coil will be built into a curved fiberglass sample holder that will both reinforce the bottom of the coil and hold the sample.


Dewar Filling
Filled the liquid nitrogen storage Dewar. Empty it weighs 76 pounds and full it weighs in at 173 pounds.  Strangely, I’m unable to figure out how to get the liquid nitrogen to exit the Dewar today.  Opening the liquid or the vent valves produces no results, (haven’t tried both yet).  The pressure gauge reads 0 psi.  The Dewar is still slightly cold to the touch though and feels still feels heavier.





Comments

Popular posts from this blog

Cool Math Tricks: Deriving the Divergence, (Del or Nabla) into New (Cylindrical) Coordinate Systems

Now available as a Kindle ebook for 99 cents ! Get a spiffy ebook, and fund more physics The following is a pretty lengthy procedure, but converting the divergence, (nabla, del) operator between coordinate systems comes up pretty often. While there are tables for converting between common coordinate systems , there seem to be fewer explanations of the procedure for deriving the conversion, so here goes! What do we actually want? To convert the Cartesian nabla to the nabla for another coordinate system, say… cylindrical coordinates. What we’ll need: 1. The Cartesian Nabla: 2. A set of equations relating the Cartesian coordinates to cylindrical coordinates: 3. A set of equations relating the Cartesian basis vectors to the basis vectors of the new coordinate system: How to do it: Use the chain rule for differentiation to convert the derivatives with respect to the Cartesian variables to derivatives with respect to the cylindrical variables. The chain ...

The Alcubierre Warp Drive Tophat Function and Open Science with Sage

I transferred yesterday's Mathematica file with the Alcubierre warp drive[2] line element and space curvature calculations to the  +Sage Mathematical Software System  today, (the files been  added to the public repository [3]).  If you haven't used Sage before, it's a Python based software package that's similar in functionality to Mathematica.  Oh, and it' free.  I also worked a little more on understanding the theory, but frankly, I made far more progress with the software than the theory.  What follows will be a little more of the Alcubierre theory, plus, a cool Sage interactive demo of one of the Alcubierre functions[1], as well as a bit about my first experience with using Sage. Theory The theory is fun, but it's moving slowly.  Here's the chalk board from this morning's discussion Alcubierre setup the derivation using something called the 3+1 formalism which means we consider space to be flat, (in this case), slices that are labelled ...

How Many Files Can You Add to a GPT Project? An Interview with GPT-5 on Limits, Context Engineering Tips, and Chats

 Setting the scene: I’m tinkering with Project TouCans, knee-deep in radio logs, SQLite dumps, and Cesium code. Naturally, I’m wondering if shoving all this into one GPT Project is a recipe for brilliance… or for disaster. So I turn to Vril — you know, after Brainy from the Legion of Super-Heroes , because what else do you call your AI sidekick who always has the answers? Time to ask him straight up. [ As an aside, yes, GPT-5 has decided to sometimes call me Vail. I'm not sure why to be honest. Also, I asked Vril, er GPT-5, to write up our interview for me. Apparently, me asking it to 'Bro' up a few stories, just for fun, has convinced Vril that I use 'Like,' more than I actually might. ] Me (Vail): So Vril, how many files can I throw into a GPT Project before it just starts choking? Like, is there some magic number where the context window taps out and everything falls apart? GPT-5 (Vril): Great question. There’s no single hard file limit. What matters is ...